A WGB | Add Wireless to G.703 routing (Administrator) |
A WGB ID:xx [par:val] |
It adds a new entry to the table of Wireless to G.703 routings in the "ID:xx" position. The command can also set eventually indicated parameters to the specified values. Not specified parameters are set to default values.
The table of Wireless to G.703 routings can store up to 4 entries, therefore the routing identifier value must be in the interval [0 - 3]. The table is not automatically maintained with consecutive indexes, then Wireless to G.703 routing definitions may not have sequential identifiers.
If an entry with the same identifier is already present in the table, is going to be added, the "WG BRIDGE ROUTING ALREADY EXISTS" error message will be shown.
If the table of Wireless to G.703 routings is full and a new routing is asked to be added, an error message is generated: "WG BRIDGE ROUTINGS TABLE IS FULL, COMMAND NOT EXECUTED".
If the Abilis CPX version, currently in use, does not support Wireless to G.703 Bridge service, the following message will be shown "WG BRIDGE ROUTINGS SERVICE NOT PRESENT".
The table of Wireless to G.703 routings can be modified while the Abilis CPX is working, but they are not immediately active, to be activated they need the system to be restarted.
The "Not Refreshed (INIT)" message is displayed every time the table is modified while the Abilis CPX is working.
The "Not Saved (SAVE CONF)" message is displayed every time the table is modified but not saved with the SAVE CONF command.
C WGB | Clear Wireless to G.703 routing (Administrator) |
C WGB ID:xx |
It deletes the specified entry from the table of Wireless to G.703 routings. The routing identifier must be in the interval [0 - 3].
If the requested entry is not present in the table, the following error message will be displayed: "WG BRIDGE ROUTING NOT PRESENT".
If the table of Wireless to G.703 routings is empty, the following message will be shown "WG BRIDGE ROUTINGS TABLE IS EMPTY".
Wireless to G.703 routings, whose identifier is higher than the deleted one, are not decremented because of table contiguity. So, the deleted definition frees a place in the table of Wireless to G.703 routings, which won't be displayed by the command D WGB.
If the Abilis CPX version, currently in use, does not support Wireless to G.703 Bridge service, the following message will be shown "WG BRIDGE ROUTINGS SERVICE NOT PRESENT".
The table of Wireless to G.703 routings can be modified while the Abilis CPX is working, but they are not immediately active, to be activated they need the system to be restarted.
The "Not Refreshed (INIT)" message is displayed every time the table is modified while the Abilis CPX is working.
The "Not Saved (SAVE CONF)" message is displayed every time the table is modified but not saved with the SAVE CONF command.
D WGB | Display Wireless to G.703 routing (User) |
D WGB D WGB ID:xx |
It shows the table of Wireless to G.703 routings.
If the identifier is omitted, the command will show all the Wireless to G.703 routings currently set.
Wireless to G.703 routing definitions may not have sequential identifiers, that 's the not shown values represent the free places in the table.
Here is an example of the command execution:
[18:14:08] ABILIS_CPX: D WGB - Not Saved (SAVE CONF), Not Refreshed (INIT) --------------------------------- ID: SRCPORT: SRCCHAN: DSTPORT: DSTCHAN: --------------------------------------------- 0 30 0 600 0 3 NONE 0 NONE 0
The "Not Refreshed (INIT)" message is displayed every time the table is modified while the Abilis CPX is working.
The "Not Saved (SAVE CONF)" message is displayed every time the table is modified but not saved with the SAVE CONF command.
If the table of Wireless to G.703 routings is empty, the following message will be shown "*** NO WG BRIDGE ROUTINGs DEFINED ***".
By specifying the Wireless to G.703 routing identifier, the command will show only the requested routing.
[18:14:08] ABILIS_CPX: D WGB ID:0 ID: SRCPORT: SRCCHAN: DSTPORT: DSTCHAN: --------------------------------------------- 0 30 0 600 0
The identifier must be in the interval [0 - 3]. If the requested entry is not present in the table, the following error message will be displayed: "WG BRIDGE ROUTING NOT PRESENT".
For a more detailed description of the shown information, refer the Configuration of Wireless to G.703 routings section.
If the Abilis CPX version, currently in use, does not support Wireless to G.703 service, the following message will be shown "WG BRIDGE ROUTINGS SERVICE NOT PRESENT".
S WGB | Set Wireless to G.703 routing (Administrator) |
S WGB ID:xx par:val [par:val] |
It sets parameters of the specified Wireless to G.703 routing to their new values.
The specified Wireless to G.703 routing identifier value must be in the interval [0 - 3]. If the requested entry is not present in the table, the following error message will be displayed: "WG BRIDGE ROUTING NOT PRESENT".
If the table of Wireless to G.703 routings is empty, the following message will be shown "WG BRIDGE ROUTINGS TABLE IS EMPTY".
The parameter list, defined in the command, is left to right evaluated: the parameters are set one after the other, starting from the leftmost. Command evaluating will terminate if one the following events will occur:
All the parameters evaluated, before the error occurrence, will get the new value, the other ones will not be changed.
The table of Wireless to G.703 routings can be modified while the Abilis CPX is working, but they are not immediately active, to be activated they need the system to be restarted.
The "Not Refreshed (INIT)" message is displayed every time the table is modified while the Abilis CPX is working.
The "Not Saved (SAVE CONF)" message is displayed every time the table is modified but not saved with the SAVE CONF command.
If the Abilis CPX version, currently in use, does not support Wireless to G.703 service, the following message will be shown "WG BRIDGE ROUTINGS SERVICE NOT PRESENT".